Matthias Reichl authored
Commit 528222d8 ("media: rc: harmonize infrared durations to microseconds") missed to switch some timeout calculations from nanoseconds to microseconds. This resulted in spurious key_up+key_down events at the last scancode if the rc device uses a long timeout (eg 100ms on nuvoton-cir) as the device timeout wasn't properly accounted for in the keyup timeout calculation. Fix this by applying the proper conversion functions. Cc: stable@vger.kernel.org Fixes: 528222d8 ("media: rc: harmonize infrared durations to microseconds") Signed-off-by: Matthias Reichl <hias@horus.com> Signed-off-by: Sean Young <sean@mess.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>