John Garry authored
If hisi_sas_task_prep() fails for a SATA device due to PHY down, we return a failure to libata and also call task_done(), which will cause ata_qc_complete() to be called twice: - first call from hisi_sas_task_prep(), which will clear flag ATA_QCFLAG_ACTIVE - ata_qc_complete() called from libata The warning call trace is as follows: [ 117.070206] [<ffff0000084f59b0>] __ata_qc_complete+0xf4/0x11c [ 117.070208] [<ffff0000084f5b58>] ata_qc_complete+0x180/0x200 [ 117.070210] [<ffff0000084f5dd0>] ata_qc_issue+0x110/0x354 [ 117.070212] [<ffff0000084f6254>] ata_exec_internal_sg+0x240/0x4d0 [ 117.070214] [<ffff0000084f6544>] ata_exec_internal+0x60/0xa0 [ 117.070217] [<ffff000008501580>] ata_read_log_page+0x188/0x1b4 [ 117.070218] [<ffff0000085017dc>] ata_eh_analyze_ncq_error+0xa8/0x274 [ 117.070220] [<ffff000008501a3c>] ata_eh_link_autopsy+0x94/0x8c8 [ 117.070222] [<ffff0000085022a4>] ata_eh_autopsy+0x34/0xe8 [ 117.070223] [<ffff00000850540c>] ata_do_eh+0x28/0xc0 [ 117.070225] [<ffff0000085054e0>] ata_std_error_handler+0x3c/0x84 [ 117.070227] [<ffff000008505140>] ata_scsi_port_error_handler+0x480/0x674 [ 117.070230] [<ffff0000084e3020>] async_sas_ata_eh+0x44/0x78 [ 117.070231] [<ffff0000080d6b8c>] async_run_entry_fn+0x40/0x104 [ 117.070234] [<ffff0000080ce518>] process_one_work+0x128/0x2f0 [ 117.070235] [<ffff0000080ce738>] worker_thread+0x58/0x434 [ 117.070237] [<ffff0000080d416c>] kthread+0xd4/0xe8 [ 117.070240] [<ffff000008084e10>] ret_from_fork+0x10/0x40 The issue is resolved by simply returning a failure status code to the upper layer. Signed-off-by: Xiang Chen <chenxiang66@hisilicon.com> Signed-off-by: John Garry <john.garry@huawei.com> Reviewed-by: Hannes Reinecke <hare@suse.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
09fe9ecb