Stefan Haberland authored
When a new CKD storage volume is defined at the storage server, Linux may be relying on outdated information about that volume, which leads to the following errors: 1. Command Reject Errors for minidisk on z/VM: dasd-eckd.b3193d: 0.0.XXXX: An error occurred in the DASD device driver, reason=09 dasd(eckd): I/O status report for device 0.0.XXXX: dasd(eckd): in req: 00000000XXXXXXXX CC:00 FC:04 AC:00 SC:17 DS:02 CS:00 RC:0 dasd(eckd): device 0.0.2046: Failing CCW: 00000000XXXXXXXX dasd(eckd): Sense(hex) 0- 7: 80 00 00 00 00 00 00 00 dasd(eckd): Sense(hex) 8-15: 00 00 00 00 00 00 00 00 dasd(eckd): Sense(hex) 16-23: 00 00 00 00 e1 00 0f 00 dasd(eckd): Sense(hex) 24-31: 00 00 40 e2 00 00 00 00 dasd(eckd): 24 Byte: 0 MSG 0, no MSGb to SYSOP 2. Equipment Check errors on LPAR or for dedicated devices on z/VM: dasd(eckd): I/O status report for device 0.0.XXXX: dasd(eckd): in req: 00000000XXXXXXXX CC:00 FC:04 AC:00 SC:17 DS:0E CS:40 fcxs:01 schxs:00 RC:0 dasd(eckd): device 0.0.9713: Failing TCW: 00000000XXXXXXXX dasd(eckd): Sense(hex) 0- 7: 10 00 00 00 13 58 4d 0f dasd(eckd): Sense(hex) 8-15: 67 00 00 00 00 00 00 04 dasd(eckd): Sense(hex) 16-23: e5 18 05 33 97 01 0f 0f dasd(eckd): Sense(hex) 24-31: 00 00 40 e2 00 04 58 0d dasd(eckd): 24 Byte: 0 MSG f, no MSGb to SYSOP Fix this problem by using the up-to-date information provided during online processing via the device specific SNEQ to detect the case of outdated LCU data. If there is a difference, perform a re-read of that data. Cc: stable@vger.kernel.org Reviewed-by: Jan Hoeppner <hoeppner@linux.ibm.com> Signed-off-by: Stefan Haberland <sth@linux.vnet.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
5d27a2bf