Takashi Iwai authored
The sync EP setup isn't cleared at stopping the stream but expected to be cleared at the next stream start. This may leave the sync link setup stale and can spoof wrongly when full duplex streams were running in the implicit fb sync. Let's initialize them properly at start and end of the stream. Tested-by: Keith Milner <kamilner@superlative.org> Tested-by: Dylan Robinson <dylan_robinson@motu.com> Link: https://lore.kernel.org/r/20201123085347.19667-7-tiwai@suse.deSigned-off-by: Takashi Iwai <tiwai@suse.de>
1803503f