Alexandre Belloni authored
When alarm value is read at boot time, at91_alarm_year is not yet set to the proper value so the year is always set to 1900. This results in that kind of message at boot: rtc rtc0: invalid alarm value: 1900-1-14 2:11:39 There is no way to recover from that as the alarm is now only read when booting. Instead, rely on the rtc core to figure out the proper year. Acked-by: Nicolas Ferre <nicolas.ferre@microchip.com> Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
eaa1dc7b