    ASoC: samsung: odroid: Fix 32000 sample rate handling · 1d22c337
    Sylwester Nawrocki authored
    In case of sample rates lower than 44100 currently there is too low MCLK
    frequency set for the CODEC. Playback fails with following errors:
    
    $ speaker-test -c2 -t sine -f 1500 -l2 -r 32000
    
    Sine wave rate is 1500.0000Hz
    Rate set to 32000Hz (requested 32000Hz)
    Buffer size range from 128 to 131072
    Period size range from 64 to 65536
    Using max buffer size 131072
    Periods = 4
    Unable to set hw params for playback: Invalid argument
    Setting of hwparams failed: Invalid argument
    
    [  497.883700] max98090 1-0010: Invalid master clock frequency
    
    To fix this the I2S root clock's frequency is increased, depending
    on sampling rate.