We don't need to init HW before every transfer since we know the HW state then. HW init at probe time is enough. While here, add setting the clock register which belongs to init HW. Also, set MDBS bit since not setting it is prohibited according to the manual. Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Signed-off-by: Wolfram Sang <wsa@the-dreams.de>