• Viresh Kumar's avatar
    arm: dts: exynos: Add missing cooling device properties for CPUs · 672f3319
    Viresh Kumar authored
    The cooling device properties, like "#cooling-cells" and
    "dynamic-power-coefficient", should either be present for all the CPUs
    of a cluster or none. If these are present only for a subset of CPUs of
    a cluster then things will start falling apart as soon as the CPUs are
    brought online in a different order. For example, this will happen
    because the operating system looks for such properties in the CPU node
    it is trying to bring up, so that it can register a cooling device.
    
    Add such missing properties.
    
    Fix other missing properties (clocks, OPP, clock latency) as well to
    make it all work.
    Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
    Signed-off-by: default avatarKrzysztof Kozlowski <krzk@kernel.org>
    672f3319
exynos4210.dtsi 11.1 KB