Ross Lagerwall authored
When a CPU is offlined, there may be unprocessed events on a port for that CPU. If the port is subsequently reused on a different CPU, it could be in an unexpected state with the link bit set, resulting in interrupts being missed. Fix this by consuming any unprocessed events for a particular CPU when that CPU dies. Signed-off-by: Ross Lagerwall <ross.lagerwall@citrix.com> Cc: <stable@vger.kernel.org> # 3.14+ Signed-off-by: David Vrabel <david.vrabel@citrix.com>