• Jacob Keller's avatar
    ice: support immediate firmware activation via devlink reload · 399e27db
    Jacob Keller authored
    The ice hardware contains an embedded chip with firmware which can be
    updated using devlink flash. The firmware which runs on this chip is
    referred to as the Embedded Management Processor firmware (EMP
    firmware).
    
    Activating the new firmware image currently requires that the system be
    rebooted. This is not ideal as rebooting the system can cause unwanted
    downtime.
    
    In practical terms, activating the firmware does not always require a
    full system reboot. In many cases it is possible to activate the EMP
    firmware immediately. There are a couple of different scenarios to
    cover.
    
     * The EMP firmware itself can be reloaded by issuing a special update
       to the device called an Embedded Management Processor reset (EMP
       reset). This reset causes the device to reset and reload the EMP
       firmware.
    
     * PCI configuration changes are only reloaded after a cold PCIe reset.
       Unfortunately there is no generic way to trigger this for a PCIe
       device without a system reboot.
    
    When performing a flash update, firmware is capable of responding with
    some information about the specific update requirements.
    
    The driver updates the flash by programming a secondary inactive bank
    with the contents of the new image, and then issuing a command to
    request to switch the active bank starting from the next load.
    
    The response to the final command for updating the inactive NVM flash
    bank includes an indication of the minimum reset required to fully
    update the device. This can be one of the following:
    
     * A full power on is required
     * A cold PCIe reset is required
     * An EMP reset is required
    
    The response to the command to switch flash banks includes an indication
    of whether or not the firmware will allow an EMP reset request.
    
    For most updates, an EMP reset is sufficient to load the new EMP
    firmware without issues. In some cases, this reset is not sufficient
    because the PCI configuration space has changed. When this could cause
    incompatibility with the new EMP image, the firmware is capable of
    rejecting the EMP reset request.
    
    Add logic to ice_fw_update.c to handle the response data flash update
    AdminQ commands.
    
    For the reset level, issue a devlink status notification informing the
    user of how to complete the update with a simple suggestion like
    "Activate new firmware by rebooting the system".
    
    Cache the status of whether or not firmware will restrict the EMP reset
    for use in implementing devlink reload.
    
    Implement support for devlink reload with the "fw_activate" flag. This
    allows user space to request the firmware be activated immediately.
    
    For the .reload_down handler, we will issue a request for the EMP reset
    using the appropriate firmware AdminQ command. If we know that the
    firmware will not allow an EMP reset, simply exit with a suitable
    netlink extended ACK message indicating that the EMP reset is not
    available.
    
    For the .reload_up handler, simply wait until the driver has finished
    resetting. Logic to handle processing of an EMP reset already exists in
    the driver as part of its reset and rebuild flows.
    
    Implement support for the devlink reload interface with the
    "fw_activate" action. This allows userspace to request activation of
    firmware without a reboot.
    
    Note that support for indicating the required reset and EMP reset
    restriction is not supported on old versions of firmware. The driver can
    determine if the two features are supported by checking the device
    capabilities report. I confirmed support has existed since at least
    version 5.5.2 as reported by the 'fw.mgmt' version. Support to issue the
    EMP reset request has existed in all version of the EMP firmware for the
    ice hardware.
    
    Check the device capabilities report to determine whether or not the
    indications are reported by the running firmware. If the reset
    requirement indication is not supported, always assume a full power on
    is necessary. If the reset restriction capability is not supported,
    always assume the EMP reset is available.
    
    Users can verify if the EMP reset has activated the firmware by using
    the devlink info report to check that the 'running' firmware version has
    updated. For example a user might do the following:
    
     # Check current version
     $ devlink dev info
    
     # Update the device
     $ devlink dev flash pci/0000:af:00.0 file firmware.bin
    
     # Confirm stored version updated
     $ devlink dev info
    
     # Reload to activate new firmware
     $ devlink dev reload pci/0000:af:00.0 action fw_activate
    
     # Confirm running version updated
     $ devlink dev info
    
    Finally, this change does *not* implement basic driver-only reload
    support. I did look into trying to do this. However, it requires
    significant refactor of how the ice driver probes and loads everything.
    The ice driver probe and allocation flows were not designed with such
    a reload in mind. Refactoring the flow to support this is beyond the
    scope of this change.
    Signed-off-by: default avatarJacob Keller <jacob.e.keller@intel.com>
    Tested-by: default avatarGurucharan G <gurucharanx.g@intel.com>
    Signed-off-by: default avatarTony Nguyen <anthony.l.nguyen@intel.com>
    399e27db