Michal Kalderon authored
The maximum number of CQs supported is bound to the number of connections supported, which differs between RoCE and iWARP. This fixes a crash that occurred in iWARP when running 1000 sessions using perftest. Fixes: 67b40dcc ("qed: Implement iWARP initialization, teardown and qp operations") Signed-off-by: Michal Kalderon <Michal.Kalderon@cavium.com> Signed-off-by: Ariel Elior <Ariel.Elior@cavium.com> Reviewed-by: Leon Romanovsky <leonro@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
471115ab