Alexander F. Lent authored
Modules that load firmware from various paths at runtime must declare those paths at compile time, via the MODULE_FIRMWARE macro, so that the firmware paths are included in the module's metadata. The accel/ivpu driver loads firmware but lacks this metadata, preventing dracut from correctly locating firmware files. Fix it. Fixes: 9ab43e95 ("accel/ivpu: Switch to generation based FW names") Fixes: 02d5b0aa ("accel/ivpu: Implement firmware parsing and booting") Signed-off-by: Alexander F. Lent <lx@xanderlent.com> Reviewed-by: Jacek Lawrynowicz <jacek.lawrynowicz@linux.intel.com> Signed-off-by: Jacek Lawrynowicz <jacek.lawrynowicz@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20240709-fix-ivpu-firmware-metadata-v3-1-55f70bba055b@xanderlent.com
58b5618b