Rafael J. Wysocki authored
Commit 9ad18043 ("thermal: core: Send trip crossing notifications at init time if needed") overlooked the case when a trip point that has started as invalid is set to a valid temperature later. Namely, the initial threshold value for all trips is zero, so if a previously invalid trip becomes valid and its (new) low temperature is above the zone temperature, a spurious trip crossing notification will occur and it may trigger the WARN_ON() in handle_thermal_trip(). To address this, set the initial threshold for all trips to INT_MAX. There is also the case when a valid writable trip becomes invalid that requires special handling. First, in accordance with the change mentioned above, the trip's threshold needs to be set to INT_MAX to avoid the same issue. Second, if the trip in question is passive and it has been crossed by the thermal zone temperature on the way up, the zone's passive count has been incremented and it is in the passive polling mode, so its passive count needs to be adjusted to allow the passive polling to be turned off eventually. Fixes: 9ad18043 ("thermal: core: Send trip crossing notifications at init time if needed") Fixes: 042a3d80 ("thermal: core: Move passive polling management to the core") Reported-by: Zhang Rui <zhang.rui@intel.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> Tested-by: Wendy Wang <wendy.wang@intel.com>
8c69a777