Ankur Kishore authored
Most of the AM43x CM reg address offsets are with MSB bit '1' (on 16-bit value) leading to arithmetic miscalculations while calculating CLOCK ENABLE register's address because cm_inst field was a type of "const s16", so make it "const u16". Also modify relevant functions so as to take care of the above. [afzal@ti.com: fixup and cleanup] Signed-off-by: Ankur Kishore <a-kishore@ti.com> Signed-off-by: Afzal Mohammed <afzal@ti.com> Acked-by: Rajendra Nayak <rnayak@ti.com> Acked-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Paul Walmsley <paul@pwsan.com>
d3f5d551