Martin Blumenstingl authored
Some Amlogic boards store the Ethernet MAC address inside the eFuse. The Ethernet MAC address uses 6 bytes. The existing logic in meson_mx_efuse_read() would write beyond the end of the data buffer when trying to read data with a size that is not aligned to word_size (4 bytes on Meson8, Meson8b and Meson8m2). Calculate the remaining data to copy inside meson_mx_efuse_read() so reading 6 bytes doesn't write beyond the end of the data buffer. Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com> Reviewed-by: Neil Armstrong <narmstrong@baylibre.com> Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org> Link: https://lore.kernel.org/r/20190818093345.29647-5-srinivas.kandagatla@linaro.orgSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
cb6b0a39