• Thomas Gleixner's avatar
    ALSA: hda: Make proper use of timecounter · 6dd21ad8
    Thomas Gleixner authored
    HDA uses a timecounter to read a hardware clock running at 24 MHz. The
    conversion factor is set with a mult value of 125 and a shift value of 0,
    which is not converting the hardware clock to nanoseconds, it is converting
    to 1/3 nanoseconds because the conversion factor from 24Mhz to nanoseconds
    is 125/3. The usage sites divide the "nanoseconds" value returned by
    timecounter_read() by 3 to get a real nanoseconds value.
    
    There is a lengthy comment in azx_timecounter_init() explaining this
    choice. That comment makes blatantly wrong assumptions about how
    timecounters work and what can overflow.
    
    The comment says:
    
         * Applying the 1/3 factor as part of the multiplication
         * requires at least 20 bits for a decent precision, however
         * overflows occur after about 4 hours or less, not a option.
    
    timecounters operate on time deltas between two readouts of a clock and use
    the mult/shift pair to calculate a precise nanoseconds value:
    
        delta_nsec = (delta_clock * mult) >> shift;
    
    The fractional part is also taken into account and preserved to prevent
    accumulated rounding errors. For details see cyclecounter_cyc2ns().
    
    The mult/shift pair has to be chosen so that the multiplication of the
    maximum expected delta value does not result in a 64bit overflow. As the
    counter wraps around on 32bit, the maximum observable delta between two
    reads is (1 << 32) - 1 which is about 178.9 seconds.
    
    That in turn means the maximum multiplication factor which fits into an u32
    will not cause a 64bit overflow ever because it's guaranteed that:
    
         ((1 << 32) - 1) ^ 2 < (1 << 64)
    
    The resulting correct multiplication factor is 2796202667 and the shift
    value is 26, i.e. 26 bit precision. The overflow of the multiplication
    would happen exactly at a clock readout delta of 6597069765 which is way
    after the wrap around of the hardware clock at around 274.8 seconds which
    is off from the claimed 4 hours by more than an order of magnitude.
    
    If the counter ever wraps around the last read value then the calculation
    is off by the number of wrap arounds times 178.9 seconds because the
    overflow cannot be observed.
    
    Use clocks_calc_mult_shift(), which calculates the most accurate mult/shift
    pair based on the given clock frequency, and remove the bogus comment along
    with the divisions at the readout sites.
    
    Fixes: 5d890f59 ("ALSA: hda: support for wallclock timestamps")
    Signed-off-by: default avatarThomas Gleixner <tglx@linutronix.de>
    Reviewed-by: default avatarPierre-Louis Bossart <pierre-louis.bossart@linux.intel.com>
    Link: https://lore.kernel.org/r/871r35kwji.ffs@tglxSigned-off-by: default avatarTakashi Iwai <tiwai@suse.de>
    6dd21ad8