James Smart authored
It's possible for the driver to initiate an FLOGI and before it completes, another link down/up transition occurs requiring a new FLOGI. Currently, nothing is done to abort/noop the older FLOGI request to the adapter, so if this transition occurs and the FLOGI completion is received after the link down/up transition, the driver may erroneously act on the older FLOGI. In most cases, the adapter properly terminates/fails the FLOGI, but there is a timing condition where the FLOGI may complete on the wire prior to the transition, but the response may not be seen/processed by the driver before the driver sees the link transition. Fix by having the link down handler in the driver run through any outstanding ELS's and change the completion handler of the ELS so that it will be no-op'd and released. Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: James Smart <jsmart2021@gmail.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
6ede2ddd