• Jan Glauber's avatar
    [S390] qdio: fix error reporting for hipersockets · 7a0b4cbc
    Jan Glauber authored
    Hipersocket connections can encounter temporary busy conditions.
    In case of the busy bit set we retry the SIGA operation immediatelly.
    If the busy condition still persists after 100 ms we fail and report
    the error to the upper layer. The second stage retry logic is removed.
    In case of ongoing busy conditions the upper layer needs to reset the
    connection.
    
    The reporting of a SIGA error is now done synchronously to allow the
    network driver to requeue the buffers. Also no error trace is created
    for the temporary SIGA errors so the error message view is not flooded.
    Signed-off-by: default avatarJan Glauber <jang@linux.vnet.ibm.com>
    Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
    7a0b4cbc
qdio.h 11.1 KB