• Anton Vorontsov's avatar
    gianfar: Implement workaround for eTSEC74 erratum · 7d350977
    Anton Vorontsov authored
    MPC8313ECE says:
    
    "If MACCFG2[Huge Frame]=0 and the Ethernet controller receives frames
     which are larger than MAXFRM, the controller truncates the frames to
     length MAXFRM and marks RxBD[TR]=1 to indicate the error. The controller
     also erroneously marks RxBD[TR]=1 if the received frame length is MAXFRM
     or MAXFRM-1, even though those frames are not truncated.
     No truncation or truncation error occurs if MACCFG2[Huge Frame]=1."
    
    There are two options to workaround the issue:
    
    "1. Set MACCFG2[Huge Frame]=1, so no truncation occurs for invalid large
     frames. Software can determine if a frame is larger than MAXFRM by
     reading RxBD[LG] or RxBD[Data Length].
    
     2. Set MAXFRM to 1538 (0x602) instead of the default 1536 (0x600), so
     normal-length frames are not marked as truncated. Software can examine
     RxBD[Data Length] to determine if the frame was larger than MAXFRM-2."
    
    This patch implements the first workaround option by setting HUGEFRAME
    bit, and gfar_clean_rx_ring() already checks the RxBD[Data Length].
    Signed-off-by: default avatarAnton Vorontsov <avorontsov@mvista.com>
    Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
    7d350977