Stanislaw Gruszka authored
On some machines mt76x0u firmware can hung during resume, what result on messages like below: [ 475.480062] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 475.990066] mt76x0 1-8:1.0: Error: send MCU cmd failed:-110 [ 475.990075] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 476.500003] mt76x0 1-8:1.0: Error: send MCU cmd failed:-110 [ 476.500012] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 477.010046] mt76x0 1-8:1.0: Error: send MCU cmd failed:-110 [ 477.010055] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 477.529997] mt76x0 1-8:1.0: Error: send MCU cmd failed:-110 [ 477.530006] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 477.824907] mt76x0 1-8:1.0: Error: send MCU cmd failed:-71 [ 477.824916] mt76x0 1-8:1.0: Error: MCU response pre-completed! [ 477.825029] usb 1-8: USB disconnect, device number 6 and possible whole system freeze. This can be avoided, if we do not perform mt76x0_chip_onoff() reset. Cc: stable@vger.kernel.org Fixes: 134b2d0d ("mt76x0: init files") Signed-off-by: Stanislaw Gruszka <sgruszka@redhat.com> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
8f2d163c