-
Johan Hovold authored
The SC8180X has two resets but the DP configuration erroneously described only one. In case the DP part of the PHY is initialised before the USB part (e.g. depending on probe order), then only the first reset would be asserted. Fixes: 1633802c ("phy: qcom: qmp: Add SC8180x USB/DP combo") Cc: stable@vger.kernel.org # 5.15 Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Signed-off-by: Johan Hovold <johan+linaro@kernel.org> Link: https://lore.kernel.org/r/20221114081346.5116-4-johan+linaro@kernel.orgSigned-off-by: Vinod Koul <vkoul@kernel.org>
910dd488