Olivier Moysan authored
Add smart calibration support for STM32MP1. - STM32MP15x: both linear & offset calibration are supported - STM32MP13x: Only offset calibration is supported Linear calibration: Linear calibration is SoC dependent and does not change over time so it can be done only once. Linear calibration may have already been done in u-boot. Skip calibration execution if calibration data are already available. Save calibration factors in private data and restore them from private data on next ADC start. Offset calibration: This calibration may vary over time, depending on temperature or voltage. Run offset single-ended and differential calibration on each ADC start, as it is not time consuming. This calibration do not need to be saved. So, remove calfact_s and calfact_d value and bitfields that are no longer used. Signed-off-by: Olivier Moysan <olivier.moysan@foss.st.com> Reviewed-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com> Link: https://lore.kernel.org/r/20221115103124.70074-2-olivier.moysan@foss.st.comSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>