Martyn Welch authored
The TSI channel, which is usually used for touchscreen support, but can be used as 4 general purpose ADCs. When used as a touchscreen interface the touchscreen driver switches the device into 1ms sampling mode (rather than the default 10ms economy mode) as recommended by the manufacturer. When using the TSI channels as a general purpose ADC we are currently not doing this and testing suggests that this can result in ADC timeouts: [ 5827.198289] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5827.728293] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5993.808335] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5994.328441] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5994.848291] da9052 spi2.0: timeout waiting for ADC conversion interrupt Switching to the 1ms timing resolves this issue. Fixes: 4f16cab1 ("hwmon: da9052: Add support for TSI channel") Signed-off-by: Martyn Welch <martyn.welch@collabora.co.uk> Acked-by: Steve Twiss <stwiss.opensource@diasemi.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
b16918a5