• Zong-Zhe Yang's avatar
    rtw89: ser: fix CAM leaks occurring in L2 reset · b169f877
    Zong-Zhe Yang authored
    The CAM, meaning address CAM and bssid CAM here, will get leaks during
    SER (system error recover) L2 reset process and ieee80211_restart_hw()
    which is called by L2 reset process eventually.
    
    The normal flow would be like
    -> add interface (acquire 1)
    -> enter ips (release 1)
    -> leave ips (acquire 1)
    -> connection (occupy 1) <(A) 1 leak after L2 reset if non-sec connection>
    
    The ieee80211_restart_hw() flow (under connection)
    -> ieee80211 reconfig
    -> add interface (acquire 1)
    -> leave ips (acquire 1)
    -> connection (occupy (A) + 2) <(B) 1 more leak>
    
    Originally, CAM is released before HW restart only if connection is under
    security. Now, release CAM whatever connection it is to fix leak in (A).
    OTOH, check if CAM is already valid to avoid acquiring multiple times to
    fix (B).
    
    Besides, if AP mode, release address CAM of all stations before HW restart.
    Signed-off-by: default avatarZong-Zhe Yang <kevin_yang@realtek.com>
    Signed-off-by: default avatarPing-Ke Shih <pkshih@realtek.com>
    Signed-off-by: default avatarKalle Valo <kvalo@kernel.org>
    Link: https://lore.kernel.org/r/20220314071250.40292-2-pkshih@realtek.com
    b169f877