Horia Geantă authored
In some cases the CCB DMA-based internal transfer started by the MOVE command (src=M3 register, dst=descriptor buffer) does not finish in time and DECO executes the unpatched descriptor. This leads eventually to a DECO Watchdog Timer timeout error. To make sure the transfer ends, change the MOVE command to be blocking. Signed-off-by: Horia Geantă <horia.geanta@nxp.com> Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>