When a raid5 (or raid6) array is being reshaped to have fewer devices, conf->raid_disks is the latter and hence smaller number of devices. However sometimes we want to use a number which is the total number of currently required devices - the larger of the 'old' and 'new' sizes. Before we implemented reducing the number of devices, this was always 'new' i.e. ->raid_disks. Now we need max(raid_disks, previous_raid_disks) in those places. This particularly affects assembling an array that was shutdown while in the middle of a reshape to fewer devices. md.c needs a similar fix when interpreting the md metadata. Signed-off-by: NeilBrown <neilb@suse.de>