-
Prathyush K authored
While powering on/off a local powerdomain in exynos5 chipsets, the input clocks to each device gets modified. This behaviour is based on the SYSCLK_SYS_PWR_REG registers. E.g. SYSCLK_MFC_SYS_PWR_REG = 0x0, the parent of input clock to MFC (aclk333) gets modified to oscclk = 0x1, no change in clocks. The recommended value of SYSCLK_SYS_PWR_REG before power gating any domain is 0x0. So we must also restore the clocks while powering on a domain everytime. This patch adds the framework for getting the required mux and parent clocks through a power domain device node. With this patch, while powering off a domain, parent is set to oscclk and while powering back on, its re-set to the correct parent which is as per the recommended pd on/off sequence. Signed-off-by: Prathyush K <prathyush.k@samsung.com> Signed-off-by: Andrew Bresticker <abrestic@chromium.org> Signed-off-by: Arun Kumar K <arun.kk@samsung.com> Signed-off-by: Shaik Ameer Basha <shaik.ameer@samsung.com> Reviewed-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
c760569d