• Vignesh Raghavendra's avatar
    serial: 8250_port: Don't service RX FIFO if throttled · f19c3f6c
    Vignesh Raghavendra authored
    When port's throttle callback is called, it should stop pushing any more
    data into TTY buffer to avoid buffer overflow. This means driver has to
    stop HW from receiving more data and assert the HW flow control. For
    UARTs with auto HW flow control (such as 8250_omap) manual assertion of
    flow control line is not possible and only way is to allow RX FIFO to
    fill up, thus trigger auto HW flow control logic.
    
    Therefore make sure that 8250 generic IRQ handler does not drain data
    when port is stopped (i.e UART_LSR_DR is unset in read_status_mask). Not
    servicing, RX FIFO would trigger auto HW flow control when FIFO
    occupancy reaches preset threshold, thus halting RX.
    Since, error conditions in UART_LSR register are cleared just by reading
    the register, data has to be drained in case there are FIFO errors, else
    error information will lost.
    Signed-off-by: default avatarVignesh Raghavendra <vigneshr@ti.com>
    Link: https://lore.kernel.org/r/20200319103230.16867-2-vigneshr@ti.comSigned-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
    f19c3f6c