Jerome Brunet authored
When using input clocks with high rates, such as clk81 (166MHz), the fin_ns = NSEC_PER_SEC / fin_freq can introduce a significant error. Ex: fin_freq = 166666667, NSEC_PER_SEC = 1000000000 fin_ns = 5,9999999 which is, of course, rounded down to 5. This introduces an error of ~20% on the period requested from the PWM. This patch uses ps instead of ns (and 64 bit integers) to perform the calculation. This should give a good enough precision. Fixes: 211ed630 ("pwm: Add support for Meson PWM Controller") Signed-off-by: Jerome Brunet <jbrunet@baylibre.com> Acked-by: Neil Armstrong <narmstrong@baylibre.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com> squash! pwm: meson: Improve pwm calculation precision