Commit 1117b31a authored by Sreekanth Reddy's avatar Sreekanth Reddy Committed by Christoph Hellwig

mpt3sas: Added OEM branding Strings

Added following branding Strings for Intel custom HBAs support.

Driver String:                                  Vendor ID       Device ID       SubSystemVendor ID      SubSystemDevice ID
Intel(R) Integrated RAID Module RMS3JC080       0x1000          0x0097          0x8086                  0x3521
Intel(R) RAID Controller RS3GC008               0x1000          0x0097          0x8086                  0x3522
Intel(R) RAID Controller RS3FC044               0x1000          0x0097          0x8086                  0x3523
Intel(R) RAID Controller RS3UC080               0x1000          0x0097          0x8086                  0x3524
Signed-off-by: default avatarSreekanth Reddy <Sreekanth.Reddy@avagotech.com>
Reviewed-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: default avatarChristoph Hellwig <hch@lst.de>
parent a4ffce0d
......@@ -2185,6 +2185,53 @@ mpt3sas_base_put_smid_default(struct MPT3SAS_ADAPTER *ioc, u16 smid)
&ioc->scsi_lookup_lock);
}
/**
* _base_display_intel_branding - Display branding string
* @ioc: per adapter object
*
* Return nothing.
*/
static void
_base_display_intel_branding(struct MPT3SAS_ADAPTER *ioc)
{
if (ioc->pdev->subsystem_vendor != PCI_VENDOR_ID_INTEL)
return;
switch (ioc->pdev->device) {
case MPI25_MFGPAGE_DEVID_SAS3008:
switch (ioc->pdev->subsystem_device) {
case MPT3SAS_INTEL_RMS3JC080_SSDID:
pr_info(MPT3SAS_FMT "%s\n", ioc->name,
MPT3SAS_INTEL_RMS3JC080_BRANDING);
break;
case MPT3SAS_INTEL_RS3GC008_SSDID:
pr_info(MPT3SAS_FMT "%s\n", ioc->name,
MPT3SAS_INTEL_RS3GC008_BRANDING);
break;
case MPT3SAS_INTEL_RS3FC044_SSDID:
pr_info(MPT3SAS_FMT "%s\n", ioc->name,
MPT3SAS_INTEL_RS3FC044_BRANDING);
break;
case MPT3SAS_INTEL_RS3UC080_SSDID:
pr_info(MPT3SAS_FMT "%s\n", ioc->name,
MPT3SAS_INTEL_RS3UC080_BRANDING);
break;
default:
pr_info(MPT3SAS_FMT
"Intel(R) Controller: Subsystem ID: 0x%X\n",
ioc->name, ioc->pdev->subsystem_device);
break;
}
break;
default:
pr_info(MPT3SAS_FMT
"Intel(R) Controller: Subsystem ID: 0x%X\n",
ioc->name, ioc->pdev->subsystem_device);
break;
}
}
/**
......@@ -2216,6 +2263,8 @@ _base_display_ioc_capabilities(struct MPT3SAS_ADAPTER *ioc)
(bios_version & 0x0000FF00) >> 8,
bios_version & 0x000000FF);
_base_display_intel_branding(ioc);
pr_info(MPT3SAS_FMT "Protocol=(", ioc->name);
if (ioc->facts.ProtocolFlags & MPI2_IOCFACTS_PROTOCOL_SCSI_INITIATOR) {
......
......@@ -130,7 +130,25 @@
#define MPT_TARGET_FLAGS_DELETED 0x04
#define MPT_TARGET_FASTPATH_IO 0x08
/*
* Intel HBA branding
*/
#define MPT3SAS_INTEL_RMS3JC080_BRANDING \
"Intel(R) Integrated RAID Module RMS3JC080"
#define MPT3SAS_INTEL_RS3GC008_BRANDING \
"Intel(R) RAID Controller RS3GC008"
#define MPT3SAS_INTEL_RS3FC044_BRANDING \
"Intel(R) RAID Controller RS3FC044"
#define MPT3SAS_INTEL_RS3UC080_BRANDING \
"Intel(R) RAID Controller RS3UC080"
/*
* Intel HBA SSDIDs
*/
#define MPT3SAS_INTEL_RMS3JC080_SSDID 0x3521
#define MPT3SAS_INTEL_RS3GC008_SSDID 0x3522
#define MPT3SAS_INTEL_RS3FC044_SSDID 0x3523
#define MPT3SAS_INTEL_RS3UC080_SSDID 0x3524
/*
* status bits for ioc->diag_buffer_status
......
Markdown is supported