staging: comedi: addi_apci_3120: remove unipolar range from analog outputs
The analog outputs of the APCI-3120 have a 14-bit bipolar range and use straight binary values (0x0000 = -10V to 0x3fff = +10V) to set the outputs. This driver tries to fake a unipolar range by munging the comedi data values to only output 0V to +10V signals (0x0000 to 0x1fff values are munged to 0x2000 - 0x3fff). This causes problems with the comedilib API functions that convert between comedi values and physical values. It's also possible for the user to pass a data value that would get munged and actually change the wrong channel. Fix this by change the subdevice range_table to range_bipolar10 and remove the munging in apci3120_ao_insn_write(). Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Reviewed-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>