staging iio adt7410: fix 13bit mode
The driver assumes that in 13bit mode the 16bit value has to be shifted to the right by 3 bits. This is not true, in both 16bit and 13bit mode the MSB is at the same position. Currently the driver returns a temperature of 194 degrees Celsius in 13bit mode and 24 degrees Celsius in 16bit mode. Fix this by using the same algorithm for 16bit and 13bit mode and by just masking out the lower three bits in 13bit mode. Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de> Acked-by: Sonic Zhang <sonic.zhang@analog.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>