Commit 1a793a10 authored by Rajkumar Kasirajan's avatar Rajkumar Kasirajan Committed by Lee Jones

ab8500-fg: Use correct battery charge full design

If battery is not identified while fg probe, mah_max_design gets
initialized with unknown battery's charge full design. Reinitialize
mah_max_design if battery is identified after fg probe.
Signed-off-by: default avatarRajkumar Kasirajan <rajkumar.kasirajan@stericsson.com>
Signed-off-by: default avatarLee Jones <lee.jones@linaro.org>
Reviewed-by: default avatarVijaya Kumar K-1 <vijay.kilari@stericsson.com>
Reviewed-by: default avatarMarcus COOPER <marcus.xm.cooper@stericsson.com>
Reviewed-by: default avatarOlivier CLERGEAUD <olivier.clergeaud@stericsson.com>
Reviewed-by: default avatarArun MURTHY <arun.murthy@stericsson.com>
Reviewed-by: default avatarRabin VINCENT <rabin.vincent@stericsson.com>
Tested-by: default avatarRupesh KUMAR <rupesh.kumar@stericsson.com>
Tested-by: default avatarJonas ABERG <jonas.aberg@stericsson.com>
parent 3988043b
......@@ -2250,7 +2250,8 @@ static int ab8500_fg_get_ext_psy_data(struct device *dev, void *data)
case POWER_SUPPLY_PROP_TECHNOLOGY:
switch (ext->type) {
case POWER_SUPPLY_TYPE_BATTERY:
if (!di->flags.batt_id_received) {
if (!di->flags.batt_id_received &&
di->bm->batt_id != BATTERY_UNKNOWN) {
const struct abx500_battery_type *b;
b = &(di->bm->bat_type[di->bm->batt_id]);
......