Commit 27931d38 authored by Marek Vasut's avatar Marek Vasut Committed by Dmitry Torokhov

Input: ili210x - reduce sample period to 15ms

Modern devices may redraw display at 60 Hz, make sure we have one input
sample per one frame. Reduce sample period to 15ms, so we would get up
to 66.6 samples per second, although realistically with all the jitter
and extra scheduling wiggle room, we would end up just above 60 samples
per second. This should be a good compromise between sampling too often
and sampling too seldom.
Signed-off-by: default avatarMarek Vasut <marex@denx.de>
Link: https://lore.kernel.org/r/20211108114145.84118-1-marex@denx.deSigned-off-by: default avatarDmitry Torokhov <dmitry.torokhov@gmail.com>
parent 8639e042
......@@ -14,7 +14,7 @@
#include <linux/slab.h>
#include <asm/unaligned.h>
#define ILI2XXX_POLL_PERIOD 20
#define ILI2XXX_POLL_PERIOD 15
#define ILI210X_DATA_SIZE 64
#define ILI211X_DATA_SIZE 43
......