Commit 35b052a6 authored by Eduardo Valentin's avatar Eduardo Valentin Committed by Greg Kroah-Hartman

staging: omap-thermal: fix error checking

The omap_bandgap_get_sensor_data() function returns ERR_PTR(),
but it can also return NULL, in case of initilization, so we need to use
IS_ERR_OR_NULL() rather than only IS_ERR().
Signed-off-by: default avatarEduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 24796e12
......@@ -260,7 +260,7 @@ int omap_thermal_expose_sensor(struct omap_bandgap *bg_ptr, int id,
data = omap_bandgap_get_sensor_data(bg_ptr, id);
if (IS_ERR(data))
if (IS_ERR_OR_NULL(data))
data = omap_thermal_build_data(bg_ptr, id);
if (!data)
......@@ -309,7 +309,7 @@ int omap_thermal_register_cpu_cooling(struct omap_bandgap *bg_ptr, int id)
struct omap_thermal_data *data;
data = omap_bandgap_get_sensor_data(bg_ptr, id);
if (IS_ERR(data))
if (IS_ERR_OR_NULL(data))
data = omap_thermal_build_data(bg_ptr, id);
if (!data)
......
Markdown is supported