Commit 381676d5 authored by Peter Meerwald's avatar Peter Meerwald Committed by Jonathan Cameron

iio:bma180: Fix scale factors to report correct acceleration units

The userspace interface for acceleration sensors is documented as using
m/s^2 units [Documentation/ABI/testing/sysfs-bus-iio]

The fullscale raw values for the BMA80 corresponds to -/+ 1, 1.5, 2, etc G
depending on the selected mode.

The scale table was converting to G rather than m/s^2.
Change the scaling table to match the documented interface.

See commit 71702e6e, iio: mma8452: Use correct acceleration units,
for a related fix.
Signed-off-by: default avatarPeter Meerwald <pmeerw@pmeerw.net>
Cc: Oleksandr Kravchenko <o.v.kravchenko@globallogic.com>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
Cc: Stable@vger.kernel.org
parent 61bd55ce
......@@ -68,13 +68,13 @@
/* Defaults values */
#define BMA180_DEF_PMODE 0
#define BMA180_DEF_BW 20
#define BMA180_DEF_SCALE 250
#define BMA180_DEF_SCALE 2452
/* Available values for sysfs */
#define BMA180_FLP_FREQ_AVAILABLE \
"10 20 40 75 150 300"
#define BMA180_SCALE_AVAILABLE \
"0.000130 0.000190 0.000250 0.000380 0.000500 0.000990 0.001980"
"0.001275 0.001863 0.002452 0.003727 0.004903 0.009709 0.019417"
struct bma180_data {
struct i2c_client *client;
......@@ -94,7 +94,7 @@ enum bma180_axis {
};
static int bw_table[] = { 10, 20, 40, 75, 150, 300 }; /* Hz */
static int scale_table[] = { 130, 190, 250, 380, 500, 990, 1980 };
static int scale_table[] = { 1275, 1863, 2452, 3727, 4903, 9709, 19417 };
static int bma180_get_acc_reg(struct bma180_data *data, enum bma180_axis axis)
{
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment