Commit 42b696e8 authored by Chanwoo Choi's avatar Chanwoo Choi Committed by Lukasz Majewski

thermal: exynos: Fix wrong control of power down detection mode for Exynos7

This patch fixes the wrong control of PD_DET_EN (power down detection mode)
for Exynos7 because exynos7_tmu_control() always enables the power down detection
mode regardless 'on' parameter.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: default avatarChanwoo Choi <cw00.choi@samsung.com>
Tested-by: default avatarAbhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: default avatarLukasz Majewski <l.majewski@samsung.com>
parent 5912e264
......@@ -682,6 +682,7 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
if (on) {
con |= (1 << EXYNOS_TMU_CORE_EN_SHIFT);
con |= (1 << EXYNOS7_PD_DET_EN_SHIFT);
interrupt_en =
(of_thermal_is_trip_valid(tz, 7)
<< EXYNOS7_TMU_INTEN_RISE7_SHIFT) |
......@@ -704,9 +705,9 @@ static void exynos7_tmu_control(struct platform_device *pdev, bool on)
interrupt_en << EXYNOS_TMU_INTEN_FALL0_SHIFT;
} else {
con &= ~(1 << EXYNOS_TMU_CORE_EN_SHIFT);
con &= ~(1 << EXYNOS7_PD_DET_EN_SHIFT);
interrupt_en = 0; /* Disable all interrupts */
}
con |= 1 << EXYNOS7_PD_DET_EN_SHIFT;
writel(interrupt_en, data->base + EXYNOS7_TMU_REG_INTEN);
writel(con, data->base + EXYNOS_TMU_REG_CONTROL);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment