Commit 471dec80 authored by Dan Murphy's avatar Dan Murphy Committed by Sebastian Reichel

dt-bindings: power: Convert battery.txt to battery.yaml

Convert the battery.txt file to yaml and fix up the examples.
Signed-off-by: default avatarDan Murphy <dmurphy@ti.com>
Reviewed-by: default avatarRob Herring <robh@kernel.org>
[Fixed the regex for ocv-capacity-table and the DT example for it]
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 466bf931
Battery Characteristics
The devicetree battery node provides static battery characteristics.
In smart batteries, these are typically stored in non-volatile memory
on a fuel gauge chip. The battery node should be used where there is
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
Upstream dts files should not include battery nodes, unless the battery
represented cannot easily be replaced in the system by one of a
different type. This prevents unpredictable, potentially harmful,
behavior should a replacement that changes the battery type occur
without a corresponding update to the dtb.
The contents of this file has been moved to battery.yaml
Please note that not all charger drivers respect all of the properties.
Required Properties:
- compatible: Must be "simple-battery"
Optional Properties:
- over-voltage-threshold-microvolt: battery over-voltage limit
- re-charge-voltage-microvolt: limit to automatically start charging again
- voltage-min-design-microvolt: drained battery voltage
- voltage-max-design-microvolt: fully charged battery voltage
- energy-full-design-microwatt-hours: battery design energy
- charge-full-design-microamp-hours: battery design capacity
- trickle-charge-current-microamp: current for trickle-charge phase
- precharge-current-microamp: current for pre-charge phase
- precharge-upper-limit-microvolt: limit when to change to constant charging
- charge-term-current-microamp: current for charge termination phase
- constant-charge-current-max-microamp: maximum constant input current
- constant-charge-voltage-max-microvolt: maximum constant input voltage
- factory-internal-resistance-micro-ohms: battery factory internal resistance
- ocv-capacity-table-0: An array providing the open circuit voltage (OCV)
of the battery and corresponding battery capacity percent, which is used
to look up battery capacity according to current OCV value. And the open
circuit voltage unit is microvolt.
- ocv-capacity-table-1: Same as ocv-capacity-table-0
......
- ocv-capacity-table-n: Same as ocv-capacity-table-0
- ocv-capacity-celsius: An array containing the temperature in degree Celsius,
for each of the battery capacity lookup table. The first temperature value
specifies the OCV table 0, and the second temperature value specifies the
OCV table 1, and so on.
- resistance-temp-table: An array providing the temperature in degree Celsius
and corresponding battery internal resistance percent, which is used to look
up the resistance percent according to current temperature to get a accurate
batterty internal resistance in different temperatures.
Battery properties are named, where possible, for the corresponding
elements in enum power_supply_property, defined in
https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h
Batteries must be referenced by chargers and/or fuel-gauges
using a phandle. The phandle's property should be named
"monitored-battery".
Example:
bat: battery {
compatible = "simple-battery";
voltage-min-design-microvolt = <3200000>;
voltage-max-design-microvolt = <4200000>;
energy-full-design-microwatt-hours = <5290000>;
charge-full-design-microamp-hours = <1430000>;
precharge-current-microamp = <256000>;
charge-term-current-microamp = <128000>;
constant-charge-current-max-microamp = <900000>;
constant-charge-voltage-max-microvolt = <4200000>;
factory-internal-resistance-micro-ohms = <250000>;
ocv-capacity-celsius = <(-10) 0 10>;
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
};
charger: charger@11 {
....
monitored-battery = <&bat>;
...
};
fuel_gauge: fuel-gauge@22 {
....
monitored-battery = <&bat>;
...
};
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/power/supply/battery.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#
title: Battery Characteristics
maintainers:
- Sebastian Reichel <sre@kernel.org>
description: |
The devicetree battery node provides static battery characteristics.
In smart batteries, these are typically stored in non-volatile memory
on a fuel gauge chip. The battery node should be used where there is
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
Upstream dts files should not include battery nodes, unless the battery
represented cannot easily be replaced in the system by one of a
different type. This prevents unpredictable, potentially harmful,
behavior should a replacement that changes the battery type occur
without a corresponding update to the dtb.
Battery properties are named, where possible, for the corresponding elements
in enum power_supply_property, defined in include/linux/power_supply.h
Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
The phandle's property should be named "monitored-battery".
properties:
compatible:
const: simple-battery
over-voltage-threshold-microvolt:
description: battery over-voltage limit
re-charge-voltage-microvolt:
description: limit to automatically start charging again
voltage-min-design-microvolt:
description: drained battery voltage
voltage-max-design-microvolt:
description: fully charged battery voltage
energy-full-design-microwatt-hours:
description: battery design energy
charge-full-design-microamp-hours:
description: battery design capacity
trickle-charge-current-microamp:
description: current for trickle-charge phase
precharge-current-microamp:
description: current for pre-charge phase
precharge-upper-limit-microvolt:
description: limit when to change to constant charging
charge-term-current-microamp:
description: current for charge termination phase
constant-charge-current-max-microamp:
description: maximum constant input current
constant-charge-voltage-max-microvolt:
description: maximum constant input voltage
factory-internal-resistance-micro-ohms:
description: battery factory internal resistance
resistance-temp-table:
description: |
An array providing the temperature in degree Celsius
and corresponding battery internal resistance percent, which is used to
look up the resistance percent according to current temperature to get an
accurate batterty internal resistance in different temperatures.
ocv-capacity-celsius:
description: |
An array containing the temperature in degree Celsius,
for each of the battery capacity lookup table.
required:
- compatible
patternProperties:
'^ocv-capacity-table-[0-9]+$':
$ref: /schemas/types.yaml#/definitions/uint32-matrix
description: |
An array providing the open circuit voltage (OCV)
of the battery and corresponding battery capacity percent, which is used
to look up battery capacity according to current OCV value. And the open
circuit voltage unit is microvolt.
maxItems: 100
items:
items:
- description: open circuit voltage (OCV) in microvolts
- description: battery capacity percent
maximum: 100
additionalProperties: false
examples:
- |
power {
#address-cells = <1>;
#size-cells = <0>;
battery: battery {
compatible = "simple-battery";
over-voltage-threshold-microvolt = <4500000>;
re-charge-voltage-microvolt = <250000>;
voltage-min-design-microvolt = <3200000>;
voltage-max-design-microvolt = <4200000>;
energy-full-design-microwatt-hours = <5290000>;
charge-full-design-microamp-hours = <1430000>;
precharge-current-microamp = <256000>;
precharge-upper-limit-microvolt = <2500000>;
charge-term-current-microamp = <128000>;
constant-charge-current-max-microamp = <900000>;
constant-charge-voltage-max-microvolt = <4200000>;
factory-internal-resistance-micro-ohms = <250000>;
ocv-capacity-celsius = <(-10) 0 10>;
/* table for -10 degree Celsius */
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
/* table for 0 degree Celsius */
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
/* table for 10 degree Celsius */
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
};
charger@11 {
reg = <0x11>;
monitored-battery = <&battery>;
};
fuel-gauge@22 {
reg = <0x22>;
monitored-battery = <&battery>;
};
};
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment