drivers: misc: ti_dac7512: Remove duplicate driver
The Texas Instruments DAC7512 has the exact same pinout, programming interface and power-down modes as the Texas Instruments DAC121S101 and Analog Devices AD5320, which are already supported by the IIO driver ad5446.c. Remove the duplicate misc driver. This requires user space to migrate to the standardized IIO sysfs ABI. (In other words, it needs to change a filename.) The IIO driver supports the chip's features more fully, e.g. the ability to power down the output or choose one of the available powerdown modes. There is an oddity with the misc driver in that it initializes the SPI slave to SPI_MODE_0, in contradiction to the datasheet which specifies that data is latched in on the falling edge, implying that SPI_MODE_1 or SPI_MODE_2 must be used. Another oddity is that Kconfig and the MODULE_DESCRIPTION() claim the chip has 16-bit resolution although it actually has 12-bit. Datasheets: http://www.ti.com/lit/ds/symlink/dac7512.pdf http://www.ti.com/lit/ds/symlink/dac121s101.pdf http://www.analog.com/media/en/technical-documentation/data-sheets/AD5320.pdfSigned-off-by: Lukas Wunner <lukas@wunner.de> Acked-by: Daniel Mack <daniel@zonque.org> Acked-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>