Commit 4e1774f3 authored by Guennadi Liakhovetski's avatar Guennadi Liakhovetski Committed by Paul Mundt

ARM: mach-shmobile: do not enable the PLLC2 clock on init

AP4EVB has to reparent PLLC2 to provide a precise HDMI clock, this is only
possible, if PLLC2 hasn't been enabled yet. Since no other driver currently
uses PLLC2 we can safely remove the CLK_ENABLE_ON_INIT flag. This fixes
the "Cannot set PLLC2 parent: -16, 1 users" error message, when trying to
use HDMI on AP4EVB.
Signed-off-by: default avatarGuennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: default avatarPaul Mundt <lethal@linux-sh.org>
parent 3572b33e
......@@ -286,7 +286,6 @@ static struct clk_ops pllc2_clk_ops = {
struct clk pllc2_clk = {
.ops = &pllc2_clk_ops,
.flags = CLK_ENABLE_ON_INIT,
.parent = &extal1_div2_clk,
.freq_table = pllc2_freq_table,
.parent_table = pllc2_parent,
......