coresight: Handle build path error
Enabling a component via sysfs (echo 1 > enable_source), would trigger building a path from the enabled sources to the sink. If there is an error in the process (e.g, sink not enabled or the device (CPU corresponding to ETM) is not online), we never report failure, except for leaving a message in the dmesg. Do proper error checking for the build path and return the error. Before: $ echo 0 > /sys/devices/system/cpu/cpu2/online $ echo 1 > /sys/devices/cs_etm/cpu2/enable_source $ echo $? 0 After: $ echo 0 > /sys/devices/system/cpu/cpu2/online $ echo 1 > /sys/devices/cs_etm/cpu2/enable_source -bash: echo: write error: No such device or address Signed-off-by: Suzuki K Poulose <suzuki.poulose@arm.com> Acked-by: Mathieu Poirier <mathieu.poirier@linaro.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>