Commit 575ea5b3 authored by Sakari Ailus's avatar Sakari Ailus Committed by Mauro Carvalho Chehab

[media] smiapp: The sensor only needs a single clock, name may be NULL

The SMIA compatible sensors only need a single clock.
Signed-off-by: default avatarSakari Ailus <sakari.ailus@iki.fi>
Signed-off-by: default avatarMauro Carvalho Chehab <mchehab@osg.samsung.com>
parent f73108eb
......@@ -2482,7 +2482,7 @@ static int smiapp_registered(struct v4l2_subdev *subdev)
}
if (!sensor->platform_data->set_xclk) {
sensor->ext_clk = devm_clk_get(&client->dev, "ext_clk");
sensor->ext_clk = devm_clk_get(&client->dev, NULL);
if (IS_ERR(sensor->ext_clk)) {
dev_err(&client->dev, "could not get clock\n");
return PTR_ERR(sensor->ext_clk);
......