ARM: dts: r8a73a4: Remove unnecessary clock-output-names properties
* Fixed rate and fixed factor clocks do not require an clock-output-names property. * Since 07705583 ("clk: shmobile: div6: Make clock-output-names optional") Renesas div6 clocks do not require a clock-output-names property. In the above cases there is only one clock output and its name is taken from that of the clock node. Accordingly, remove the unnecessary clock-output-names properties and as necessary update the node names. The clock-output-names property is left in place for the zb_clk which is thus treated as a special case as the MSTP clock driver (clk-mstp.c) explicitly looks for a clock with node name zb_clk for the r8a73a4 and sh73a0 SoCs. Signed-off-by: Simon Horman <horms+renesas@verge.net.au> Acked-by: Geert Uytterhoeven <geert+renesas@glider.be>
Showing
Please register or sign in to comment