Commit 5cd16d8c authored by Ido Schimmel's avatar Ido Schimmel Committed by David S. Miller

mlxsw: cmd: Update CONFIG_PROFILE command documentation

The meaning of certain parameters in the profile passed to the device
during initialization has changed, so update their documentation
accordingly.
Signed-off-by: default avatarIdo Schimmel <idosch@mellanox.com>
Signed-off-by: default avatarJiri Pirko <jiri@mellanox.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 801bd3de
......@@ -570,7 +570,7 @@ MLXSW_ITEM32(cmd_mbox, config_profile, set_max_vlan_groups, 0x0C, 6, 1);
*/
MLXSW_ITEM32(cmd_mbox, config_profile, set_max_regions, 0x0C, 7, 1);
/* cmd_mbox_config_profile_set_fid_based
/* cmd_mbox_config_profile_set_flood_mode
* Capability bit. Setting a bit to 1 configures the profile
* according to the mailbox contents.
*/
......@@ -651,12 +651,8 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_vlan_groups, 0x28, 0, 12);
MLXSW_ITEM32(cmd_mbox, config_profile, max_regions, 0x2C, 0, 16);
/* cmd_mbox_config_profile_max_flood_tables
* Maximum number of Flooding Tables. Flooding Tables are associated to
* the different packet types for the different switch partitions.
* Note that the table size depends on the fid_based mode.
* In SwitchX silicon, tables are split equally between the switch
* partitions. e.g. for 2 swids and 8 tables, the first 4 are associated
* with swid-1 and the last 4 are associated with swid-2.
* Maximum number of single-entry flooding tables. Different flooding tables
* can be associated with different packet types.
*/
MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4);
......@@ -667,12 +663,14 @@ MLXSW_ITEM32(cmd_mbox, config_profile, max_flood_tables, 0x30, 16, 4);
*/
MLXSW_ITEM32(cmd_mbox, config_profile, max_vid_flood_tables, 0x30, 8, 4);
/* cmd_mbox_config_profile_fid_based
* FID Based Flood Mode
* 00 Do not use FID to offset the index into the Port Group Table/Multicast ID
* 01 Use FID to offset the index to the Port Group Table (pgi)
* 10 Use FID to offset the index to the Port Group Table (pgi) and
* the Multicast ID
/* cmd_mbox_config_profile_flood_mode
* Flooding mode to use.
* 0-2 - Backward compatible modes for SwitchX devices.
* 3 - Mixed mode, where:
* max_flood_tables indicates the number of single-entry tables.
* max_vid_flood_tables indicates the number of per-VID tables.
* max_fid_offset_flood_tables indicates the number of FID-offset tables.
* max_fid_flood_tables indicates the number of per-FID tables.
*/
MLXSW_ITEM32(cmd_mbox, config_profile, flood_mode, 0x30, 0, 2);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment