pwm: lp3943: Fix duty calculation in case period was clamped
The hardware only supports periods <= 1.6 ms and if a bigger period is requested it is clamped to 1.6 ms. In this case duty_cycle might be bigger than 1.6 ms and then the duty cycle register is written with a value bigger than LP3943_MAX_DUTY. So clamp duty_cycle accordingly. Fixes: af66b3c0 ("pwm: Add LP3943 PWM driver") Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>