hpsa: correct skipping masked peripherals
The SA controller spins down RAID drive spares. A REGNEWD event causes an inquiry to be sent to all physical drives. This causes the SA controller to spin up the spare. The controller suspends all I/O to a logical volume until the spare is spun up. The spin-up can take over 50 seconds. This can result in one or both of the following: - SML sends down aborts and resets to the logical volume and can cause the logical volume to be off-lined. - a negative impact on the logical volume's I/O performance each time a REGNEWD is triggered. Reviewed-by: Scott Teel <scott.teel@microsemi.com> Reviewed-by: Kevin Barnett <kevin.barnett@microsemi.com> Signed-off-by: Don Brace <don.brace@microsemi.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Showing
Please register or sign in to comment