Commit 714d0ffa authored by Vladimir Oltean's avatar Vladimir Oltean Committed by David S. Miller

net: mscc: ocelot: limit vlan ingress filtering to actual number of ports

The VSC7514 switch (Ocelot) is a 10-port device, while VSC9959 (Felix)
is 6-port. Therefore the VLAN filtering mask would be out of bounds when
calling for this new switch. Fix that.
Signed-off-by: default avatarVladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent c7282d38
......@@ -389,7 +389,8 @@ static void ocelot_vlan_init(struct ocelot *ocelot)
/* Set vlan ingress filter mask to all ports but the CPU port by
* default.
*/
ocelot_write(ocelot, GENMASK(9, 0), ANA_VLANMASK);
ocelot_write(ocelot, GENMASK(ocelot->num_phys_ports - 1, 0),
ANA_VLANMASK);
for (port = 0; port < ocelot->num_phys_ports; port++) {
ocelot_write_gix(ocelot, 0, REW_PORT_VLAN_CFG, port);
......