Commit 77d641ba authored by Luca Ceresoli's avatar Luca Ceresoli Committed by Sebastian Reichel

power: supply: core: add POWER_SUPPLY_HEALTH_NO_BATTERY

Some chargers can keep the system powered from the mains even when no
battery is present. It this case none of the currently defined health
statuses applies. Add a new status to report that no battery is present.
Suggested-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: default avatarLuca Ceresoli <luca@lucaceresoli.net>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent f9a09de3
......@@ -413,7 +413,7 @@ Description:
"Over voltage", "Unspecified failure", "Cold",
"Watchdog timer expire", "Safety timer expire",
"Over current", "Calibration required", "Warm",
"Cool", "Hot"
"Cool", "Hot", "No battery"
What: /sys/class/power_supply/<supply_name>/precharge_current
Date: June 2017
......
......@@ -106,6 +106,7 @@ static const char * const POWER_SUPPLY_HEALTH_TEXT[] = {
[POWER_SUPPLY_HEALTH_WARM] = "Warm",
[POWER_SUPPLY_HEALTH_COOL] = "Cool",
[POWER_SUPPLY_HEALTH_HOT] = "Hot",
[POWER_SUPPLY_HEALTH_NO_BATTERY] = "No battery",
};
static const char * const POWER_SUPPLY_TECHNOLOGY_TEXT[] = {
......
......@@ -66,6 +66,7 @@ enum {
POWER_SUPPLY_HEALTH_WARM,
POWER_SUPPLY_HEALTH_COOL,
POWER_SUPPLY_HEALTH_HOT,
POWER_SUPPLY_HEALTH_NO_BATTERY,
};
enum {
......