Input: ads7846 - fix integer overflow on Rt calculation
In some rare cases the 32 bit Rt value will overflow if z2 and x is max, z1 is minimal value and x_plate_ohms is relatively high (for example 800 ohm). This would happen on some screen age with low pressure. There are two possible fixes: - make Rt 64bit - reorder calculation to avoid overflow The second variant seems to be preferable, since 64 bit calculation on 32 bit system is a bit more expensive. Fixes: ffa458c1 ("spi: ads7846 driver") Co-developed-by: David Jander <david@protonic.nl> Signed-off-by: David Jander <david@protonic.nl> Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de> Link: https://lore.kernel.org/r/20201113112240.1360-1-o.rempel@pengutronix.deSigned-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>