Commit 8360e81b authored by Aristeu Rozanski's avatar Aristeu Rozanski Committed by Linus Torvalds

edac i5000: fix thermal issues

Make the Thermal messages (temperature got past Tmid) be displayed only
once because:

1) it's the BIOS job to configure and handle the memory throttling
2) if the BIOS is broken or is aware about the condition, flooding the
   system logs won't help anything.
3) According to the specification update for Intel 5000 MCHs, all the
   revisions of this MCH have problems on the thermal sensors, making
   not automatic (a.k.a. intelligent thermal throttling) impossible.
Signed-off-by: default avatarAristeu Rozanski <aris@redhat.com>
Signed-off-by: default avatarDoug Thompson <dougthompson@xmission.com>
Cc: Alan Cox <alan@lxorguk.ukuu.org.uk>
Signed-off-by: default avatarAndrew Morton <akpm@linux-foundation.org>
Signed-off-by: default avatarLinus Torvalds <torvalds@linux-foundation.org>
parent c0667407
......@@ -511,8 +511,23 @@ static void i5000_process_fatal_error_info(struct mem_ctl_info *mci,
"retry";
break;
case FERR_FAT_M3ERR:
{
static int done;
/*
* This error is generated to inform that the intelligent
* throttling is disabled and the temperature passed the
* specified middle point. Since this is something the BIOS
* should take care of, we'll warn only once to avoid
* worthlessly flooding the log.
*/
if (done)
return;
done++;
specific = ">Tmid Thermal event with intelligent "
"throttling disabled";
"throttling disabled";
}
break;
}
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment